{"product_id":"seplos-bms-48v-200a-13s-14s-ncm-15s-16s-lfp-lifepo4-lithium-ion-battery-management-system-bms","title":"Seplos BMS 48V 200A 13S 14S NCM 15S 16S LFP Lifepo4 Lithium ion Battery Management System BMS","description":"\u003ctable align=\"center\" border=\"1\" cellpadding=\"5\" cellspacing=\"0\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eBattery type and serial number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\" rowspan=\"1\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eLFP(16S)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\" rowspan=\"1\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eNCM(14S)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eContinuously charging\/discharging current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"1\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e50A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e100A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e150A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e200A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e50A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e100A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e150A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e200A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eCommunication protocol\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"8\" rowspan=\"1\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eCANBUS(defult) RS485(Please contact Sale man)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eCustom function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"8\" rowspan=\"1\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eHeating function,External switch,RS485 protocol\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eDischarge Output Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"8\" rowspan=\"1\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u0026lt;2mΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eWorking Temperture\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"8\" rowspan=\"1\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e-20℃-70℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003ecompensating impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"8\" rowspan=\"1\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e10mΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003ePre-charging\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"8\" rowspan=\"1\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e0-3000ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eCurrent limiting(charging)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"8\" rowspan=\"1\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e10A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd rowspan=\"1\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eCurrent Balance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"1\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003ePassive balance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"8\" rowspan=\"1\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e150mA(Max)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd rowspan=\"2\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003ePower consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eWorking mode power consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"8\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u0026lt;40mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eSleeping mode power consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"8\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e0uA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd rowspan=\"2\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eCapacity protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eNominal capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"8\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e5-500Ah\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eRemaining capacity protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"8\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd rowspan=\"3\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eShort Circuit protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eShort circuit protection lock\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"8\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eContinuously short in the output circuit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eShort circuit protection lock times\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"8\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e5 times\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eShort circuit protection lock release\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"8\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eConnected with charger\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd rowspan=\"2\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eIndividual cell voltage protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eOver voltage protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e3650mV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e4200mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eUnder voltage protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2700mV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2900mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd rowspan=\"2\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eVoltage protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eOver voltage protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e57.6V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e58V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eUnder voltage protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e41.6V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e40.6V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd rowspan=\"2\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eCurrent protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eOver current protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e60A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e110A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e160A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e210A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e60A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e110A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e160A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e210A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eOver current protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"8\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e30mS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd rowspan=\"2\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eHeating function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eStart\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"8\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e0℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eStop\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"8\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e10℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eNotices:\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eTechnology upgrade :\u003cbr data-mce-fragment=\"1\"\u003eThe BMS can add module now,check below for detail:\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eWith Bluetooth modules,user can manage the battery on the phone conveniently;\u003cbr data-mce-fragment=\"1\"\u003eand with h\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eeating modules,user can make sure there is heat enough to run the battery Systems when temperature below 0 ℃ or even below -20℃.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eBMS Functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eMonitoring:\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eVoltage: total voltage, voltages of individual cells, minimum and maximum cell voltage.​​\u003cbr data-mce-fragment=\"1\"\u003eTemperature: environment temperature, temperature of cells and BMS PCB.\u003cbr data-mce-fragment=\"1\"\u003eState of charge: indicate the charge level of the battery.\u003cbr data-mce-fragment=\"1\"\u003eCurrent: current in or out of the battery.\u003cbr data-mce-fragment=\"1\"\u003eCANBUS 24\/48V  8S\/16S 200A lithium iron phosphate battery smart monitoring management system 1\u003cbr data-mce-fragment=\"1\"\u003eCommunication:\u003cbr data-mce-fragment=\"1\"\u003eCANBUS communication\u003cbr data-mce-fragment=\"1\"\u003eOur BMS can support up to 16 units in parallel operation.\u003cbr data-mce-fragment=\"1\"\u003eRS485 communication(RS485 can be customize)\u003c\/span\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cspan data-mce-fragment=\"1\"\u003ePS\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e:When we want to view the battery pack parameters through the battery parameter monitoring software, we need to use the Rj45 to USB Adapter to connect the battery pack to the computer. We recommend that you purchase an Rj45 to USB Adapter from us.Adapters purchased from the market may not work properly due to the definition of the hardware\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eProtection:\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eOver voltage protection ​\u003cbr data-mce-fragment=\"1\"\u003eCapacity protection\u003cbr data-mce-fragment=\"1\"\u003ePre-chargeing function\u003cbr data-mce-fragment=\"1\"\u003eCurrent limiting\u003cbr data-mce-fragment=\"1\"\u003eUnder voltage protection\u003cbr data-mce-fragment=\"1\"\u003eCharge, discharge and ambient temperature protection\u003cbr data-mce-fragment=\"1\"\u003eCharge and discharge over current protection\u003cbr data-mce-fragment=\"1\"\u003eCharge current limitation\u003cbr data-mce-fragment=\"1\"\u003eShort circuit protection\u003cbr data-mce-fragment=\"1\"\u003eCustom function:\u003cbr data-mce-fragment=\"1\"\u003eHeating function\u003cbr data-mce-fragment=\"1\"\u003eExternal switch\u003cbr data-mce-fragment=\"1\"\u003eRS485 protocol\u003c\/span\u003e\u003c\/div\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eEqualizing function:\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cspan data-mce-fragment=\"1\"\u003ePassive equalization\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003c\/div\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003e\n\u003cspan data-mce-fragment=\"1\"\u003eCommunication methods:\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003c\/h2\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\n\u003cspan data-mce-fragment=\"1\"\u003eCANBUS communication method:\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003c\/h3\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eNow our CANBUS communication board supports these brands of inverters,and our BMS has built-in CANBUS protocol of matching inverter brand, which can be automatically matched or manually switched:\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eThe default is the Pylontech CANBUS protocol\u003cbr data-mce-fragment=\"1\"\u003eGoodwe\u003cbr data-mce-fragment=\"1\"\u003eGrowatt(The default is SPF(off-grid) protocol. If your inverter is SPH(on-grid) , please contact the sales person)\u003cbr data-mce-fragment=\"1\"\u003eVictron\u003cbr data-mce-fragment=\"1\"\u003eLUXPOWER\u003cbr data-mce-fragment=\"1\"\u003eSofar\u003cbr data-mce-fragment=\"1\"\u003eDeye\u003cbr data-mce-fragment=\"1\"\u003eSermatec\u003cbr data-mce-fragment=\"1\"\u003eRenac\u003cbr data-mce-fragment=\"1\"\u003eTBB POWER\u003cbr data-mce-fragment=\"1\"\u003eSolis\u003cbr data-mce-fragment=\"1\"\u003eSMA\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eFoxess\u003cbr data-mce-fragment=\"1\"\u003e​IMEON\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003ePS:If the inverter brand not in the listed,please ask your inverter supplier for the protocol define.And sent it to us,we 'll help confirm that\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eRS485 communication method\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eNow our RS485 communication board supports these brands of inverters,The BMS with RS485 communication has a built-in RS485 protocol, please confirm with the salesman before buying what you need is that one RS485 protocol:\u003cbr data-mce-fragment=\"1\"\u003eThe default is the Pylontech RS485 protocol\u003cbr data-mce-fragment=\"1\"\u003eVoitronic\u003cbr data-mce-fragment=\"1\"\u003ePhocos\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eGrowatt\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003ePS:If the inverter brand not in the listed,please ask your inverter supplier for the protocol define.And sent it ti us,we'll help confirm that.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eFAQ\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e1.\u003cbr data-mce-fragment=\"1\"\u003eQ: Can the 485 version and CAN version of the V14 BMS change the baud rate of the BMS by refreshing the program？\u003cbr data-mce-fragment=\"1\"\u003eA: NO, they are different version of the chip.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e2.\u003cbr data-mce-fragment=\"1\"\u003eQ: Is it an equalizing function, active or passive and what is the equalizing current?\u003cbr data-mce-fragment=\"1\"\u003eA:It’s a passive equalizing function with 150mA current.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e3.\u003cbr data-mce-fragment=\"1\"\u003eQ: What is the connection mode of communication when BMS communicates with inverter or 485 communication and CAN communication?\u003cbr data-mce-fragment=\"1\"\u003eA: External communication means that BMS is connected to CANBUS interface when communicating with inverter (RS485 interface is used for communication with Voltonic inverter)\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e4.\u003cbr data-mce-fragment=\"1\"\u003eQ: The BMS cannot work and indicator does not light up.\u003cbr data-mce-fragment=\"1\"\u003eA: May be caused by D4 diode damage.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e5.\u003cbr data-mce-fragment=\"1\"\u003eQ: Which BMS model suitable for ternary lithium battery?\u003cbr data-mce-fragment=\"1\"\u003eA:The ternary lithium battery can support up to 14S version of the BMS. The firmware version of the ternary lithium battery BMS is different from the lithium iron phosphate BMS and cannot be used universally.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e6.\u003cbr data-mce-fragment=\"1\"\u003eQ: SMA and Victron inverter will report fault when BMS is fully charged.\u003cbr data-mce-fragment=\"1\"\u003eA: The fault can be solved by refreshing the firmware program (version 2.8). The V16 BMS does not have this fault.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e7.\u003cbr data-mce-fragment=\"1\"\u003eQ: Voltronic inverter and its licensed inverter only have 485 communication version of BMS or new version of BMS (V16 version). How to use the inverter?\u003cbr data-mce-fragment=\"1\"\u003eA: The Voltonic inverter uses RS485 interface for communication. DIP dialing is different from other versions of BMS. Connect and dial 1on to the host, 2on to the first slave, and 3on to the second slave. You can ask me to send relevant documents.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e8.\u003cbr data-mce-fragment=\"1\"\u003eQ: How is BMS function of SOC calculating and cycle life counting work?\u003cbr data-mce-fragment=\"1\"\u003eA: First, modify the rated capacity of the battery, then complete a full charge and discharge process,the actual battery capacity will be learned.SOC is calculated by capacity accumulation and voltage calibration.\u003cbr data-mce-fragment=\"1\"\u003e  It has the function of calculating the number of charging and discharging cycles. When the cumulative discharge capacity of the battery pack reaches the set full capacity.At 20% (default), the number of cycles increases one,the set value of battery cycle capacity parameter can be changed through the upper computer.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e9.\u003cbr data-mce-fragment=\"1\"\u003eQ: The issue of battery monitoring software cannot see the master when multiple BMS are in parallel.\u003cbr data-mce-fragment=\"1\"\u003eA:When multiple BMS are in parallel, the battery monitoring software cannot see the information of the master, only see the information of the slave. If you want to see the information of the master, you need to turn off the DIP of the master and connect it separately or use the LCD screen with Bluetooth function, or use the onboard BMS with Bluetooth function.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e10.\u003cbr data-mce-fragment=\"1\"\u003eQ: Why not message display on LCD screen?\u003cbr data-mce-fragment=\"1\"\u003eA: 1.The function of LCD did not open.\u003cbr data-mce-fragment=\"1\"\u003e    2.Poor contact of connecting or broken wire of LCD screen.\u003cbr data-mce-fragment=\"1\"\u003e    3.The new version BMS with Bluetooth, but install with an LCD screen without Bluetooth.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e11.\u003cbr data-mce-fragment=\"1\"\u003eQ:limited algorithm of charge current.\u003cbr data-mce-fragment=\"1\"\u003eA:Unbalanced in current distributed.\u003cbr data-mce-fragment=\"1\"\u003e1.no charge current if any device is in charging warning of voltage,temperature,and capacity or charging protection.\u003cbr data-mce-fragment=\"1\"\u003e2.charge current values remain in 10.0A when no device in charging.\u003cbr data-mce-fragment=\"1\"\u003e3.charge current is base the role if over current is greater than 20.0A then reduce 10.0A,otherwise,remain in 10.0A when single device is charging.\u003cbr data-mce-fragment=\"1\"\u003e4.charge current is base the role of over current value multiply by device’s quantity then divide by two if more than two device is charging.\u003cbr data-mce-fragment=\"1\"\u003e5.charge current will be cleared and set the chargeable value to 0A when any single cell voltage more than +30mV compare to over voltage protection value with battery pack in parallel.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e12.\u003cbr data-mce-fragment=\"1\"\u003eQ:what if customer want to purchase BMS but the inverter in use is not in compatible list.\u003cbr data-mce-fragment=\"1\"\u003eA:Customer need to provide the communication protocol of their inverter.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e13.\u003cbr data-mce-fragment=\"1\"\u003eQ:Battery monitoring software not working or load protocol failure.\u003cbr data-mce-fragment=\"1\"\u003eA:1.Download new program.2.set the correct format language(as below)\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cimg alt=\"BMS\" src=\"https:\/\/site-1306369054.file.myqcloud.com\/5238231383873796\/m43Cjx5JP50.11999662957033341?imageMogr2\/format\/webp\/auto-orient\" data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e14.\u003cbr data-mce-fragment=\"1\"\u003eQ:The functions of heating and heating pad choosing.\u003cbr data-mce-fragment=\"1\"\u003eA:BMS with heating function need to customized because the heating pad size is not specific,customer need to purchased by themself and current can not over 4A.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e15.\u003cbr data-mce-fragment=\"1\"\u003eQ:The specification of 12V BMS in series or in parallel.\u003cbr data-mce-fragment=\"1\"\u003eA:In series or in parallel is available but only individually,4 BMS is limited in series but no limit in parallel.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e16.\u003cbr data-mce-fragment=\"1\"\u003eQ:About firmware program upgrade.\u003cbr data-mce-fragment=\"1\"\u003eA:Not allow to upgrade the Firmware program without permission,after sales service is not available if its cause any damage.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e17.\u003cbr data-mce-fragment=\"1\"\u003eQ:The temperature shows at -50℃\u003cbr data-mce-fragment=\"1\"\u003eA:NTC temperature sensor damaged or welding disengaged.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e18.\u003cbr data-mce-fragment=\"1\"\u003eQ:The conditions to use one key to power on\/off.\u003cbr data-mce-fragment=\"1\"\u003eA:Master BMS can control slave one to power on or off when battery working in parallel.it could not be one key to power on\/off if master address is not dial(the new version BMS can be dial automatically) and all BMS is not in standby mode(because current of the battery will flow each other if there is not in standby mode when in parallel).\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e19.\u003cbr data-mce-fragment=\"1\"\u003eQ:Is it the BMS can change to another model to use by load the parameter?\u003cbr data-mce-fragment=\"1\"\u003eA:NO(such as 13S and 14S,15S and 16S can be changed by load the parameter,but this will not recommended because it could be lead to malfunction)\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e20.\u003cbr data-mce-fragment=\"1\"\u003eQ:Running normal but there is busbar over voltage warming.\u003cbr data-mce-fragment=\"1\"\u003eA:Please check if battery circuit connection is correct.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e21.\u003cbr data-mce-fragment=\"1\"\u003eQ:Is there any other way can know the status of BMS?\u003cbr data-mce-fragment=\"1\"\u003eA:1.browse on PC software.2.check the message on LCD screen.3.check the status of LED in BMS(as description of manual)\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003c\/p\u003e","brand":"Solkit monteringssystemer til Solceller","offers":[{"title":"Default Title","offer_id":44378483491138,"sku":"SK-BAT-007","price":2500.0,"currency_code":"DKK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/4339\/8722\/products\/Skaermbillede2023-01-14231418.png?v=1673735014","url":"https:\/\/shop.solkit.dk\/products\/seplos-bms-48v-200a-13s-14s-ncm-15s-16s-lfp-lifepo4-lithium-ion-battery-management-system-bms","provider":"Solkit  monteringssystemer til Solceller","version":"1.0","type":"link"}